CP (Carrier Profile)
This command applies to the XBee 3 Cellular LTE-M/NB-IoT.
Configures the cellular component to select network operator settings (RF bands, packet data configuration) for various networks.
The 1 (No Profile) setting should be used if the module is not able to join the network because the underlying cellular modem does not have a predefined profile that supports the inserted SIM card. The 1 (No Profile) setting does not use any predefined profiles, which forces the module to attempt to join an appropriate network based on the module's current configuration.
Changes to the value only take effect on boot so a reboot or power cycle is required for any changes to become active.
Parameter range
0 - 3
Value | Description |
---|---|
0 |
Autodetect from inserted ICCID (SIM). This is the default. Setting to 0 increases the boot time. |
1 | No Profile |
2 | AT&T |
3 |
Verizon Note This value should only be used with Verizon home network SIM cards. Setting the value to 3 with other SIM cards may adversely affect network registration and activity. |
Default
0