********************************************************************************
Patch Notes for Serial Flash Support Update 19-May-2015
********************************************************************************
*** 24-Nov-2015 Updated to include RCM4310 and BL4S200. Both of these
products require a recomple with a patched version of Dynamic C.
Effective May 2015, several Rabbit brand boards are impacted by a serial
flash end of life. For the boards in the table shown below, the replacement
serial flash part requires applications to be recompiled with a patched
version of Dynamic C. The table below shows the boards impacted, the first
board revision impacted, and the required patch version of Dynamic C.
| Rabbit Product | Part No | Rev+ | Patch Part # | Software Version |
|----------------+-------------+------+----------------+------------------|
| RCM6700 | 20-101-1318 | G | 40002882_B.zip | Dynamic C 10.72 |
| RCM6710 | 20-101-1319 | G | | |
| RCM6750 | 20-101-1320 | H | | |
| RCM6760 | 20-101-1321 | H | | |
| RCM6600W | 20-101-1322 | F | | |
| RCM6650W | 20-101-1323 | F | | |
| RCM4200 | 20-101-1131 | G | | |
| RCM4210 | 20-101-1132 | G | | |
| RCM4310 | 20-101-1139 | L | | |
| RCM5400W | 20-101-1246 | K | | |
| BL5S220 | 20-101-1260 | H | | |
| BL4S110 | 20-101-1256 | G | | |
| BL4S200 | 20-101-1220 | J | | |
|----------------+-------------+------+----------------+------------------|
| RCM3305 | 20-101-1067 | E | 40002882_B.zip | Dynamic C 9.62 |
| RCM3315 | 20-101-1068 | E | | |
| RCM3319 | 20-101-1195 | G | | |
| RCM3700 | 20-101-1305 | C | | |
| RCM3710 | 20-101-1328 | C | | |
| RCM3720 | 20-101-1329 | C | | |
Installation
Unzip the archive to a location on your hard drive. The patch is structured
by Dynamic C version and as an overlay to your existing installation.
To use the patch, simply copy the patch over your existing version of
Dynamic C to replace your existing files with the patched versions of the
same.
Recompililation Required
Recompilation of your existing application is required for all affected
products listed in the table above. In other words, if your product's part
number is at the revision listed or a later revision, then you will need to
build a new binary image with the patched version of Dynamic C. Note that
the binary image will work with both new revision and older revisions of the
products.
Previous Versions of Dynamic C
Customers using previous versions of Dynamic C must upgrade to the
version listed in the table above in order to use the patch.
Patch available on the Dynamic C page on Digi's website:
Dynamic C 9.62/10.72 Adesto Patch
********************************************************************************
Last updated:
Jan 01, 2024