power_cycle_on_unbind

Globally enable and disable the power cycle on disconnect feature. When enabled, the power to each USB device is cycled by default when it disconnects from a PC.

The power cycle on disconnect feature is globally enabled by default for all groups and ports on the Hub. You can choose to globally disable this feature if desired.

Note This feature is disabled by default on the AnywhereUSB Plus 24 variant without Wi-Fi. If your device has a serial number greater than or equal to AW24-010000, this feature can be enabled. Otherwise, the feature does not work as expected and should not be enabled.

Note You can also disable this feature from the web UI. See Disable the power cycle on disconnect feature.

Syntax

config service anywhereusb power_cycle_on_unbind enable <true|false>

Parameters

true|false: Enter false to disable the feature. Enter true to enable the feature.

 

© 2024 Digi International Inc. All rights reserved.